this post was submitted on 03 Aug 2023
29 points (89.2% liked)

homeassistant

12055 readers
40 users here now

Home Assistant is open source home automation that puts local control and privacy first. Powered by a worldwide community of tinkerers and DIY enthusiasts. Perfect to run on a Raspberry Pi or a local server. Available for free at home-assistant.io

founded 1 year ago
MODERATORS
 

Right now if the pool timer is switched off, the SWG stays on. Likewise, if I switch the Shelly off and switch the timer on, the SWG stays off (and the pump turns on). Checking the SW terminal with a voltage sensor, it is hot when the pool timer is switched on, and dead when switched off. The workaround right now is the setting the schedule feature to closely match what the timer is doing.

Any ideas?

you are viewing a single comment's thread
view the rest of the comments
[–] Godnroc@lemmy.world 3 points 1 year ago (1 children)

I'll start by apologizing for not knowing anything about anything in this arrangement, but I did read a little up on that Shelly relay.

If I understand right, you are just using the Saltwater Generator (SWG) while the timer is active? The timer triggers the relay through the switch input (SW) and that causes power to turn on the output terminal (O). I assume you are using the Shelly with the input in switch mode so that it is on when the timer is on and off when the timer is off.

The issue you are having is that the SWG is still on even after the timer has turned off? It almost sounds like perhaps the settings are not in switch mode and are instead in button mode. My understanding is that it would cause the SWG to turn off-on or on-off for every full off-on-off cycle of the timer.

Hope that helps a little!

[–] FapFlop@lemmy.world 1 points 1 year ago* (last edited 1 year ago) (1 children)

Switch mode is set to ‘Follow’. I do see now that the page is showing the input as ‘OFF’ where previously it wasn’t changing from ‘ON.’ Perhaps some leaking current or a massive delay.

More testing tomorrow!

Edit: Current leak confirmed. :( Randomly went back to ON and switched it on. But at least I know it’s not a Shelly issue?

[–] Faceman2K23@discuss.tchncs.de 1 points 1 year ago

Lots of reports out there of people having current leak issues when doing anything more than the usual light switch configuration. Personally, I'd just put a dumb power meter on it and leave the chlorinator hooked up to the pump line.