this post was submitted on 24 Jul 2023
67 points (95.9% liked)

Selfhosted

40041 readers
729 users here now

A place to share alternatives to popular online services that can be self-hosted without giving up privacy or locking you into a service you don't control.

Rules:

  1. Be civil: we're here to support and learn from one another. Insults won't be tolerated. Flame wars are frowned upon.

  2. No spam posting.

  3. Posts have to be centered around self-hosting. There are other communities for discussing hardware or home computing. If it's not obvious why your post topic revolves around selfhosting, please include details to make it clear.

  4. Don't duplicate the full text of your blog or github here. Just post the link for folks to click.

  5. Submission headline should match the article title (don’t cherry-pick information from the title to fit your agenda).

  6. No trolling.

Resources:

Any issues on the community? Report it using the report flag.

Questions? DM the mods!

founded 1 year ago
MODERATORS
 

I see this as an absolute win. Be careful, folks. Just because it's DC doesn't mean it won't cause serious damage.

Edit for Clarification: When done correctly, the batteries should not arc. My problem is I did not wire the array correctly the first and a-hem second times. It only cost me one battery, which is a lot cheaper than a trip to an American ER.

you are viewing a single comment's thread
view the rest of the comments
[–] Chup@feddit.de 3 points 1 year ago (2 children)

Hm I have not heard about such an issue so far but I also don't have as many UPS as you.

I see you holding a red cable which could be +. When I switch UPS batteries, I do it the same way as it's recommended for car batteries to avoid sparks/arcs. Remove - (black) first, as it won't spark/arc. Then remove + (red) as it can't get a circuit closed any more, so also no spark/arc.

When plugging a car battery in, it's the other way around. + (red) goes in first and only then you connect - (black) to avoid spark/arc for both connectors again that way.

[–] MangoPenguin@lemmy.blahaj.zone 12 points 1 year ago (2 children)

Either polarity will arc the same, the reason on cars for doing negative first is because you're supposed to attach it to the frame, so a spark doesn't set off any hydrogen in the battery and cause an explosion.

[–] skilltheamps@feddit.de 1 points 1 year ago (1 children)

Additionally, if you where to drop a clamp or touch something by accident, it is most likely to contact negative, as that is the whole chassis. If you adhere to this order and drop the negative clamp, it will most likely just reconnect to negative. If you drop the positive clamp on the negative chassis nothing happens anymore, as you broke the circuit beforehand.

That's a good point as well.

[–] BCsven@lemmy.ca 1 points 1 year ago

The frame is already grounded negatively. so if you remove red and happen to touch red post while leaning on metal car you make a circuit. so you pull negative first so even if you touch red it can't travel back to the battery

[–] BobsAccountant@lemmy.world 5 points 1 year ago* (last edited 1 year ago)

Oh no. Half of this post is me making fun of myself. Mistakes were made. When you have a large array of batteries, it's important to wire them up correctly when replacing them. I definitely closed the circuit on some of the batteries when I shouldn't have.

I see how it could be confusing, and in the spirit of sending the correct message, I have added a clarifying edit.