this post was submitted on 24 Aug 2024
954 points (99.2% liked)

Lemmy Shitpost

26948 readers
3233 users here now

Welcome to Lemmy Shitpost. Here you can shitpost to your hearts content.

Anything and everything goes. Memes, Jokes, Vents and Banter. Though we still have to comply with lemmy.world instance rules. So behave!


Rules:

1. Be Respectful


Refrain from using harmful language pertaining to a protected characteristic: e.g. race, gender, sexuality, disability or religion.

Refrain from being argumentative when responding or commenting to posts/replies. Personal attacks are not welcome here.

...


2. No Illegal Content


Content that violates the law. Any post/comment found to be in breach of common law will be removed and given to the authorities if required.

That means:

-No promoting violence/threats against any individuals

-No CSA content or Revenge Porn

-No sharing private/personal information (Doxxing)

...


3. No Spam


Posting the same post, no matter the intent is against the rules.

-If you have posted content, please refrain from re-posting said content within this community.

-Do not spam posts with intent to harass, annoy, bully, advertise, scam or harm this community.

-No posting Scams/Advertisements/Phishing Links/IP Grabbers

-No Bots, Bots will be banned from the community.

...


4. No Porn/ExplicitContent


-Do not post explicit content. Lemmy.World is not the instance for NSFW content.

-Do not post Gore or Shock Content.

...


5. No Enciting Harassment,Brigading, Doxxing or Witch Hunts


-Do not Brigade other Communities

-No calls to action against other communities/users within Lemmy or outside of Lemmy.

-No Witch Hunts against users/communities.

-No content that harasses members within or outside of the community.

...


6. NSFW should be behind NSFW tags.


-Content that is NSFW should be behind NSFW tags.

-Content that might be distressing should be kept behind NSFW tags.

...

If you see content that is a breach of the rules, please flag and report the comment and a moderator will take action where they can.


Also check out:

Partnered Communities:

1.Memes

2.Lemmy Review

3.Mildly Infuriating

4.Lemmy Be Wholesome

5.No Stupid Questions

6.You Should Know

7.Comedy Heaven

8.Credible Defense

9.Ten Forward

10.LinuxMemes (Linux themed memes)


Reach out to

All communities included on the sidebar are to be made in compliance with the instance rules. Striker

founded 1 year ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[–] Pika@sh.itjust.works 24 points 3 months ago* (last edited 3 months ago) (1 children)

We call them a Deadman's cable up here, and sadly they're still quite frequently used in the northern rural areas because it costs almost $2,000 to have a dedicated bypass switch installed(generator hookup) so nobody does it, they just throw the Main and hope they don't put too much stress on the internal lines.

Is it legal? Hell no but they do it anyway

[–] Omega_Jimes@lemmy.ca 17 points 3 months ago (2 children)

I did this.
Is it stupid? Yes. Did it work? Also yes. For the amount of time that we'd have power out, it was just way to easy to throw a breaker and connect it like this just to keep a small heater and a light running. If I had the money at the time I would have loved battery backup/ bypass but this cost $2 and an old cord.

[–] Pika@sh.itjust.works 5 points 3 months ago* (last edited 3 months ago)

Especially considering that having a functional stove nowadays skyrockets your insurance. A lot of people used to use wood stoves as the backup heat source if the power went out, we still have one ourselves however it's "non-functional" , it probably is to be honest it hasn't been ran for a few years now but it was going to Skyrocket the insurance if we had it listed as a functional Appliance

[–] Duamerthrax@lemmy.world 3 points 3 months ago

There are way cheaper ways to have a safe interconnect then those second box systems. There are kits that install a plate next to the main breaker and prevent both the main breaker and the next closest breaker from both being on at the same time. You then setup the second breaker to be your generator inlet. Here's a DIY version, but there are kits for all major brands.