Selfhosted
A place to share alternatives to popular online services that can be self-hosted without giving up privacy or locking you into a service you don't control.
Rules:
-
Be civil: we're here to support and learn from one another. Insults won't be tolerated. Flame wars are frowned upon.
-
No spam posting.
-
Posts have to be centered around self-hosting. There are other communities for discussing hardware or home computing. If it's not obvious why your post topic revolves around selfhosting, please include details to make it clear.
-
Don't duplicate the full text of your blog or github here. Just post the link for folks to click.
-
Submission headline should match the article title (don’t cherry-pick information from the title to fit your agenda).
-
No trolling.
Resources:
- selfh.st Newsletter and index of selfhosted software and apps
- awesome-selfhosted software
- awesome-sysadmin resources
- Self-Hosted Podcast from Jupiter Broadcasting
Any issues on the community? Report it using the report flag.
Questions? DM the mods!
view the rest of the comments
Man. That AIMS low frequency inverter is nice.
I actually bought one of those cheaper Chinese pure sine wave inverters, but found that they don't run motors/power tools that well. The surge current demand just exceeds anything they can provide. They're great for resistive loads like PCs/LEDs/Hotplates, but if you wanted to run a table saw or something the AIMS is the only way.
Cheaper or not, isn't a huge factor.
My really expensive sol-ark 12k cannot start my 110v air-compressor.
The issue is, the rated L.R.A. ie, locked rotor amps, how much current it takes to get it started.
My A/C motor, for example, uses around 20 amps @ 240v when running, ie ~5,000w. However, its L.R.A, is 112.0 amps @ 220v, ie- (24,640 watts). Which is more than the peak load my 12k inverter can handle. So- if you tried to start it on the inverter, well, it doesn't work.
https://static.xtremeownage.com/blog/2023/off-grid-ac/
The same principle applies to anything with a motor.
You have to evaluate the L.R.A. Remember, if you have say, a 5,000watt RMS inverter, which can handle a 10k peak- its not going to be able to start something that has a 14,000 startup draw.