There should be a capacitor between REGN and ground and BAT and ground.
Ask Electronics
For questions about component-level electronic circuits, tools and equipment.
Rules
1: Be nice.
2: Be on-topic (eg: Electronic, not electrical).
3: No commercial stuff, buying, selling or valuations.
4: Be safe.
Oooh, thanks.
Stupid schematic question for a second, when looking at this:
If the "REGN" above the LED there is just referring to the REGN pin right below, why doesn't the line just go back down to the pin? Is this just a style thing, or does it mean something functionally different?
It means the same thing. I would have just drawn a line since they are right next to each other.
Thanks!
I could be wrong, but I did finish a degree in EE even if I just do software now. But here's my quick take on it.
Probably because you're driving voltage on STAT from REGN.
STAT should have a current limiting resistor on it, go through your led, then ground.
REGN should have a 2.2uf cap between the pin and ground according to the datasheet.
STAT should have a current limiting resistor on it, go through your led, then ground.
That would make sense, but page 21 of the datasheet with a typical application shows it going to REGN.
If it's missing the cap on REGN though, that would probably fuck this all up? I must admit I'm not good at understanding when/where caps are applied.
If you don’t mind me asking: what is this for? Is it a hobby? I have no idea if any of this, just somehow came across your post
Long term hobby that I'm trying to now turn into a small business / online store.